Mouse Angiotensinogen (AGT) ELISA Kit

Alternative:ANHU; SERPINA8; Angiotensin; Renin Substrate; Serpin Peptidase Inhibitor,Clade A,Member 8(Alpha-1 Antiproteinase,Antitrypsin)

Detection Range:7.8-500ng/mL

Sensitivity:3.8ng/mL

Assay Type:Sandwich

Product Name:

Mouse Angiotensinogen (AGT) ELISA Kit

Cat.#:

KB12297

Regulatory Status:

RUO

Alternative:

ANHU; SERPINA8; Angiotensin; Renin Substrate; Serpin Peptidase Inhibitor,Clade A,Member 8(Alpha-1 Antiproteinase,Antitrypsin)

Detection Method:

ELISA

Assay Type:

Sandwich

Detection Range:

7.8-500ng/mL

Sensitivity:

3.8ng/mL

Specificity:

This kit recognizes Mouse AGT in samples. No significant cross-reactivity or interference between Mouse AGT and analogues was observed.

Sample Type:

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Research Area:

Cardiovascular Biology


| AGT

Angiotensinogen is an alpha-2-globulin synthesized in the liver that is a precursor to angiotensin, but has also been noted to have many other effects unrelated to angiotensin peptides.It is a member of the serotonin family and has another name: serum protein A8, but it is not known to inhibit other enzymes like most serotonins.Angiotensinogen is also known as a renin substrate.It is cleaved by renin at the N-terminus to produce angiotensin I, which is subsequently modified to angiotensin II. The peptide is 485 amino acids long, and when renin acts on it, the N-terminal 10 amino acids are cleaved.Plasma angiotensinogen levels are increased by plasma corticosterone, estrogen, thyroid hormone, and angiotensin II levels.


| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

  

Concentration (ng/mL)50025012562.531.215.67.80
OD2.221.560.920.630.420.250.180.01
Corrected OD2.141.480.840.550.340.170.1-

 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse AGT spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 

Sample TypeRange(%)Average Recovery(%)
Serum(n=8)84-10196
Plasma(n=8)92-106103
Cell Culture Supernates(n=8)96-108105






 

| Linearity

Samples were spiked with high concentrations of Mouse AGT and diluted with Universal Diluent to produce samples with values within the range of the assay.

 



Serum(n=4)Plasma(n=4)Cell Culture Supernates(n=4)
1 : 2Range (%)84-9588-9590-110
Average (%)919296
1 : 4Range (%)89-10387-108105-114
Average (%)9498107








 